Home Steel Joist Institute
Preview
3 hours ago Your Resource for Steel Joist Construction. Search through our numerous resources written by SJI members and academic researchers, which include publications, design tools, webinars, technical papers and articles related to the design, manufacture and behavior of steel joists and Joist Girders. View Resources.
1. Joist Investigation FormNeed to identify older joists found in the field? SJI will help you make a proper …
2. MembersSJI members are steel joist manufacturers in the U.S., Canada and Mexico. Click …
3. Load TablesThese tables originally appeared in the Steel Joist Institute Specifications and …
4. Historical Load TablesDescription. These tables originally appeared in the Steel Joist Institute …
See Also: Open web steel joist catalog Show details
ADVERTISEMENT
Joist & Joist Girders Vulcraft
Preview
2 hours ago In accordance with the standards set by the Steel Joist Institute (SJI), Vulcraft manufactures a full range of joists, including standard joists, joist girders, and composite joists, designed to work compositely with the concrete slab that is placed on top of the steel deck, creating a …
See Also: Steel joist catalog Show details
SJI code of standard practice New Millennium …
Preview
9 hours ago Discover the easiest way to specify steel joists and Joist Girders: 197. SJI Code of Standard Practice. 177. CODE OF STANDARD PRACTICE FOR STEEL JOISTS AND JOIST GIRDERS . CODE OF STANDARD PRACTICE . FOR STEEL JOISTS AND JOIST GIRDERS . Adopted by the Steel Joist Institute April 7, 1931 Revised to May 18, 2010 - Effective December 31, 2010
See Also: Free Catalogs Show details
Steel joists and joist girders New Millennium Building
Preview
9 hours ago above, have been reproduced from the Steel Joist Institute, 43rd Edition, Standard Specifications, Load Tables and Weight Tables for Steel Joists and Joist Girders. Refer to the Steel Joist Institute website at www.steeljoist.org for the entire ANSI approved document. Pages identified with the New Millennium Building Systems
See Also: Free Catalogs Show details
FOR KSERIES, LHSERIES, AND DLHSERIES OPEN
Preview
3 hours ago American National Standard SJI 100 - 2015 Page 2 of 38 panel points of the Joist Girders unless otherwise specified. The Joist Girder standard designation in ASD shall be established by its nominal depth in inches (mm), the letter “G”, followed by the number of joist spaces, the letter “N”, and finally the load in kips (kN) at each panel point, and the letter
See Also: Free Catalogs Show details
ADVERTISEMENT
Joists Joist and Joist Girders Catalogue
Preview
3 hours ago It is also a practical guide for Canam joists and joist girders . Canam reserves the right to change, revise, or withdraw any product or procedure without notice . The information presented in this catalog was prepared according to recognized engineering principles and …
See Also: Free Catalogs Show details
VULCRAFT BRIDGING GUIDE
Preview
4 hours ago Steel Joist Institute – SJI COSP - 2015 17 TABLE 2.7-1 MAXIMUM JOIST SPACING FOR HORIZONTAL BRIDGING SPANS OVER 60 ft. (18.3 m) REQUIRE BOLTED DIAGONAL BRIDGING JOIST SECTION NUMBER1 Nominal Unfactored Force Pbr lbs (N) BRIDGING MATERIAL SIZE2 Equal Leg Angles 1 x 7/64 (25 x 3 mm) r = 0.20” (5.08 mm) 1-1/4 x 7/64 (32 …
See Also: Craft Catalogs Show details
Vulcraft Joist Girders Product Catalog
Preview
8 hours ago Joists & Deck NEBRASKA 1601WestOmahaAvenue Norfolk,Nebraska 68701 P.O.Box59 Norfolk,Nebraska 68702 (402)644-8500• Fax:(402)644-8528 email:[email protected] ISO9001Certified ISO14001Certified Joists & Deck NEW YORK 5362RailroadStreet P.O.Box280 Chemung,NewYork 14825 (607)529-9000• Fax:(607)529-9001 email:[email protected]
See Also: Craft Catalogs Show details
LONGSPAN AND DEEP LONGSPAN STEEL JOISTS, LHAND …
Preview
3 hours ago Steel Joist Institute SECTION 101. DEFINITION SECTION 102. MATERIALS . 102.2 MECHANICAL PROPERTIES The yield strength used as a basis for the design stresses prescribed in Section 103 shall be at least 36 ksi (250 MPa), but shall not be greater than 50 ksi (345 MPa). Evidence that the steel furnished meets or
See Also: Spa Templates Show details
Standard Specifications UMD
Preview
4 hours ago Series Joists by the Steel Joist Institute and the American Institute of Steel Construction. 1966 Development and introduction by the SJI and AISC of the LJ-Series Joists, which replaced the LA-Series Joists. Also, the development of a single specification for both the LJ-and the LH-Series Joists, with the use of 36,000 psi mini-
File Size: 850KB
Page Count: 14
See Also: Free Catalogs Show details
JOIST GIRDERS INTRODUCTION
Preview
2 hours ago Joist Girder. IJG = 0.027 NPLd; where N = number of joist spaces, P = panel point load in kips, L = Joist Girder length in feet), and d = effective depth of the Joist Girder in inches, or IJG = .3296 NPLd; where N = number of joist spaces, P = panel point load in kilonewtons, L = Joist Girder length in millimeters, and d = effective depthof the
See Also: Free Catalogs Show details
Open Web Steel Joists: Watch the Camber Metal
Preview
5 hours ago The SJI camber is based on an arc radius of 3,627 feet for joists up to a 100-foot span. The specification states: "Joists shall have approximate camber in accordance with the following," and: "The specifying professional shall give consideration to coordinating joist camber with adjacent framing."
See Also: Free Catalogs Show details
Design of Steel Joists and Roof Decks
Preview
6 hours ago Steel Joist Institute • SJI Standard seat depth • Most Joist Girders 7 ½ inches • Left of blue line • Large Joist Girders 10 inches or more • Right of blue line See charts in Vulcraft catalog BETTER PARTNERS. BETTER PRODUCTS. BETTER OUTCOMES. Increased Depths Required • Uplift • For high uplift, end web size will increase
See Also: Design Templates Show details
ADVERTISEMENT
THE NEW 2005 UNIFIED STEEL JOIST SPECIFICATIONS
Preview
9 hours ago The Steel Joist Institute (SJI) is the governing body for joist manufacturers who produce, on a continuing basis, joists of the K-, LH- and DLH-Series and/or Joist Girders conforming to the Institute’s Specifications and Load Tables. These manufacturers have also fulfilled the requirements for membership as described in the 42nd
See Also: Free Catalogs Show details
Joist Steel Store
Preview
1 hours ago It is the responsibility of the purchaser to ensure that any joists (and bridging) purchased will be selected, erected and used properly. Steel Joist Institute (SJI) specifications, SJI Code of Standard Practice and Handling and Erection per SJI Technical Digest #9 must be followed.
See Also: Free Catalogs Show details
An Overview of Open Web Steel Joists
Preview
6 hours ago efforts resulted in the formation of the Steel Joist Institute (SJI), which published its first set of Standard Specifications for Open Web Steel Joists in 1928, followed by the first load tables in 1929. Today, the SJI, a nonprofit organization of active joist manufacturers, By Ben COOk aND Jerry mAly Wiss, Janney, Elstner Associates, Inc.
See Also: Free Catalogs Show details
Steel Joists, Steel Deck Fabrication Canam Buildings
Preview
2 hours ago Joists and Joist Girders. Canam Buildings specializes in the manufacture of steel joists in a variety of shapes, sizes and geometries. Joists are custom-made structural steel components used to support the floors or roof of a building. The use of a system of steel joists and steel deck is a solution of choice resulting in significant savings.
See Also: Free Catalogs Show details